A-Z ELEKTRO březen / duben 2012
41 Literatura: [1] PERERA, Frederica, Zhigang LI, David CAMANN. Prenatal Airborne Polycyclic Aromatic Hydrocarbon Exposure and Child IQ at Age 5 Years. PEDIATRICS. 2009, s. 195–202. DOI: 10.1542/ peds.2008-3506. ISSN: 0031-4005. Dostupné z: http://pediatrics. aappublications.org/content/124/2/e195.full.pdf [2] Envirotemp FR3 Fluid. In Cooper Power Systems [online]. 2012 [cit. 2012-07-02]. Dostupné z WWW: < http://www.coope- rindustries.com/content/dam/public/powersystems/resources/ library/900_Fluids/90020.pdf>. [3] MIDEL 7131 Complete Binder of Data Sheets. In M&I Materials [online]. 2012 [cit. 2012-07-02]. Dostupné z WWW: <http://www.midel.com/uploads/midel/documents/technical/ MIDEL_7131_Complete_Binder_of_Data_Sheets.pdf> Vlastnosti olejů Minerální olej (typické hodnoty) Envirotempt FR3 MIDEL 7131 Elektrická pevnost [kV/ 2,5mm] ≥ 70 35 ≥ 70 Kinematická viskozita [mm 2 s -1 ] 40 °C ≤ 11 ≤ 50 ≤ 30 Bod vzplanutí [°C] ≥ 144 326 275 Bod hoření [°C] 180 362 322 Bod tuhnutí [°C] ≤ −40 −21 −60 Číslo kyselosti [mgKOHg -1 ] ≤ 0,015 0,02 0,01 Obsah vody [ppm] ≤ 30 ≤ 80 ≤ 50 Relativní permitivita [−] 2,2 3,1 3,2 Biologická odbouratelnost za 21 dní [%] 15 > 99 > 90 věda a výzkum Ztrátový činitel systémů olej-papír při teplotním stárnutí 90°C Inc., 2011, s. 575–578. ISBN: 978-1-4577-0986-9, ISSN: 0084-9162 TRNKA, P., PIHERA, J., POLANSKÝ, R., PROSR, P. Transformer Insulation – Modifications in Liquid Part. In Anals of DAAAM for 2011 & Proceedings. Vídeň: DAAAM International Vienna 2011, 2011, s. 13–14. ISBN: 978-3- 901509-83-4, ISSN: 1726-9679 SOUČEK, J., SVOBODA, M., TRNKA, P. Relation of electro insulating fluids to the environment. In Diagnostika ’11. Plzeň: Západočeská univerzita, 2011, s. 181–184. ISBN: 978-80-261-0020-1 PIHERA, J., TRNKA, P., MENTLÍK, V., ŠIRŮ- ČEK, M., MRÁZ, P. Corona Discharge within Organic Oil Insulations. In 2011 IEEE International Conference on Die- lectric Liquids. Trondheim: SINTEF Energi AS, 2011. ISBN: 978-82-594-3525-5 TRNKA, P., MENTLÍK, V., PIHERA, J., POLAN- SKÝ, R., PROSR, P. Comparison of Simulated Life Cycles of Paper-oil Insulation Systems Based on Biodegradable Fluids. In Proceedings of International Conference on Di- electric Liquid. Trondheim: Sintef Energi AS, 2011, s. 1–4. ISBN: 978-82-594-3525-5 SOUČEK, J. Vliv vlhkosti na elektrickou pevnost elektro- izolačních kapalin a vztah elektroizolačních kapalin k život- nímu prostředí. In Elektrotechnika a informatika 2011, část první – elektrotechnika. Plzeň: Západočeská univerzita, 2011, s. 119–122. ISBN: 978-80-261-0016-4
Made with FlippingBook
RkJQdWJsaXNoZXIy Mjk3NzY=